Daikin RXYQ96PYDN Service Manual page 292

R-410a heat pump 60hz, r-410a heat recovery 60hz
Hide thumbs Also See for RXYQ96PYDN:
Table of Contents

Advertisement

SiUS34-801A_b
Ceiling Mounted Built-in Type
Model
1 Cooling Capacity
2 Heating Capacity
Casing / Color
Dimensions: (H×W×D)
Rows × Stages × FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output
Fan
Air Flow Rate (H/L)
External Static Pressure
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Machine Weight (Mass)
5 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Model
Panel Color
Decoration
Panel
Dimensions: (H×W×D)
(Option)
Weight
Standard Accessories
Drawing No.
Notes:
Indoor Unit
FXSQ30MVJU
Btu/h
Btu/h
Galvanized Steel Plate
11-7/8 × 55-1/8 × 31-1/2"
in (mm)
(301.6 x 1400 x 800 mm)
3 × 14 × 14
ft²
3D18H2A
Sirocco Fan
kW
cfm
4
in. Aq
0.57-0.39
Direct Drive
Microprocessor Thermostat for Cooling
and Heating
Glass Fiber
Resin Net (with Mold Resistant)
φ3/8" (9.5 mm) (Flare Connection)
in (mm)
φ5/8" (15.8 mm) (Flare Connection)
in (mm)
in (mm)
(External Dia. 1-1/4 (31.7 mm)
Internal Dia. 1) (25.4 mm)
Lbs (kg)
119 lbs (54 kg)
dBA
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
BYBS125DJW1
White (10Y9/0.5)
2-1/8 × 59 × 19-5/8"
in (mm)
(54 x 1499 x 498.4 mm)
Lbs (kg)
14 lbs (6.3 kg)
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers.
1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB, 67°FWB
Outdoor temperature: 95°FDB
Equivalent ref. piping length: 25 ft (7.5 m) (Horizontal)
2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB.
Outdoor temperature: 47°FDB, 43°FWB
Equivalent ref. piping length: 25 ft (7.5 m) (Horizontal)
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 External static pressure is changeable to change over the connectors inside electrical box, this pressure means
"High static pressure – Standard".
5 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
these values are normally somewhat higher as a result of installation conditions.
30,000
34,000
Galvanized Steel Plate
11-7/8 × 55-1/8 × 31-1/2"
(301.6 x 1400 x 800 mm)
3.64
0.22
950/720
Microprocessor Thermostat for Cooling
Resin Net (with Mold Resistant)
φ3/8" (9.5 mm) (Flare Connection)
φ5/8" (15.8 mm) (Flare Connection)
VP25
(External Dia. 1-1/4 (31.7 mm)
Internal Dia. 1) (25.4 mm)
45/39
Fuse,
Thermal Protector for Fan Motor
Electronic Expansion Valve
2-1/8 × 59 × 19-5/8"
(54 x 1499 x 498.4 mm)
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers.
FXSQ36MVJU
36,000
40,000
3 × 14 × 14
3.64
3D18H2A
Sirocco Fan
0.22
990/740
0.57-0.35
Direct Drive
Microprocessor Thermostat for Cooling
and Heating
Glass Fiber
Resin Net (with Mold Resistant)
φ3/8" (9.5 mm) (Flare Connection)
φ5/8" (15.8 mm) (Flare Connection)
VP25
(External Dia. 1-1/4 (31.7 mm)
119 lbs (54 kg)
45/39
Fuse,
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
BYBS125DJW1
White (10Y9/0.5)
14 lbs (6.3 kg)
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers.
C:3D042684
Specifications
FXSQ48MVJU
48,000
54,000
Galvanized Steel Plate
11-7/8 × 55-1/8 × 31-1/2"
(301.6 x 1400 x 800 mm)
3 × 14 × 14
3.64
3D18H2A
Sirocco Fan
0.22
1,300/950
0.34-0.10
Direct Drive
and Heating
Glass Fiber
VP25
Internal Dia. 1) (25.4 mm)
122 lbs (55.3 kg)
48/43
Fuse,
R-410A Series
BYBS125DJW1
White (10Y9/0.5)
2-1/8 × 59 × 19-5/8"
(54 x 1499 x 498.4 mm)
14 lbs (6.3 kg)
277