Daikin RXYQ96PYDN Service Manual page 293

R-410a heat pump 60hz, r-410a heat recovery 60hz
Hide thumbs Also See for RXYQ96PYDN:
Table of Contents

Advertisement

Specifications
Ceiling Mounted Duct Type
Model
1 Cooling Capacity
2 Heating Capacity
Casing / Color
Dimensions: (H×W×D)
Rows × Stages × FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output
Fan
Air Flow Rate (H/L)
External Static Pressure
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Machine Weight (Mass)
6 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
278
FXMQ30MVJU
Btu/h
30,000
Btu/h
34,000
Galvanized Steel Plate
15-3/8 × 28-3/8 × 27-1/8"
inch (mm)
(390 x 720.7 x 689 mm)
3×16×13
ft²
D11/2D3AA1VE
Sirocco Fan
kW
cfm
690/565
4
in. Aq
0.66-0.43
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
φ3/8" (9.5 mm) (Flare Connection)
inch (mm)
φ5/8" (15.8 mm)(Flare Connection)
inch (mm)
inch (mm)
External Dia. 1-1/4(31.75 mm)
Internal Dia. 1
Lbs (kg)
99 lbs (44.9 kg)
dBA
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation
Manual, Drain Hose, Clamp Metal,
Insulation for Fitting, Sealing Pads,
Clamps, Screws.
1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB, 67°FWB
Outdoor temperature: 95°FDB
Equivalent ref. piping length: 25 ft (7.5 m) (Horizontal)
2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB.
Outdoor temperature: 47°FDB, 43°FWB
Equivalent ref. piping length: 25 ft (7.5 m) (Horizontal)
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 External static pressure is changeable to change over the connectors inside electrical box, this pressure means
"High static pressure – Standard".
5 Air filter is not standard accessory, but please mount it in the duct system of the suction side.
Select its colorimetric method (gravity method) 50% or more.
6 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
these values are normally somewhat higher as a result of installation conditions.
Galvanized Steel Plate
15-3/8 × 43-3/4 × 27-1/8"
(390 x 1111 x 689 mm)
1.95
2D11/2D3AG1VE
0.15
Microprocessor Thermostat for Cooling
5
φ3/8" (9.5 mm) (Flare Connection)
φ5/8" (15.8 mm) (Flare Connection)
VP25
External Dia. 1-1/4(31.75 mm)
(25.4 mm)
Internal Dia. 1
139 lbs (63. kg)
45/41
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws.
FXMQ36MVJU
36,000
40,000
3×16×13
3.43
Sirocco Fan
0.27
1,020/810
0.71-0.43
Direct Drive
Microprocessor Thermostat for
and Heating
Glass Fiber
5
φ3/8" (9.5 mm) (Flare Connection)
φ5/8" (15.8 mm) (Flare Connection)
VP25
External Dia. 1-1/4(31.75 mm)
(25.4 mm)
Internal Dia. 1
45/41
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation
Manual, Drain Hose, Clamp Metal,
Insulation for Fitting, Sealing Pads,
Clamps, Screws.
C:3D042685
SiUS34-801A_b
FXMQ48MVJU
48,000
54,000
Galvanized Steel Plate
15-3/8 × 43-3/4 × 27-1/8"
(390 x 1111 x 689 mm)
3×16×13
3.43
2D11/2D3AF1VE
Sirocco Fan
0.43
1,270/1,020
1.0-0.72
Direct Drive
Cooling and Heating
Glass Fiber
5
VP25
(25.4 mm)
144 lbs (65.3 kg)
48/45
Fuse,
R-410A Series
Indoor Unit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents