Charging Station Internal Fuse - Omron Pioneer LX User Manual

Omron adept mobile robots platforms for research, education and development
Table of Contents

Advertisement

Table of Contents
WARNING: Unplug power from the charging station before starting.
Remove the power cord at the charger.
The fuse assembly can be removed by squeezing the two tabs toward each other, and pulling it away
from the charging station. The fuses are p/n 04563-000. See the following figure.

Charging Station Internal Fuse

Symptoms: When the charging station is switched on, the blue power light does not come on, but the
charging station can charge a battery manually.
WARNING: Unplug power from the charging station before starting.
The charging station cover is NOT interlocked. Remove the power cord at the charger.
1.
Remove the ten screws from the back cover of the charging station.
Two of these are on the sides, near the bottom.