MIDI Implementation
7EH
ID number (Universal Non-realtime Message)
dev
Device ID (dev: 00H - 1FH (1 - 32), the initial value is 10H (17).)
7CH
ID number (Wait)
ppH
Packet number
F7H
EOX (End Of Exclusive)
Data Transmission
This instrument can use exclusive messages to exchange many varieties of internal settings
with other devices.
he model ID of the exclusive messages used by this instrument is 00H 10H.
Data Request 1RQ1 (11H)
This message requests the other device to transmit data. The address and size indicate the
type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able to
transmit data, and if the address and size are appropriate, the requested data is transmitted
as a Data Set 1 (DT1) message. If the conditions are not met, nothing is transmitted.
Status
Data Byte
F0H
41H, dev, 00H, 10H, 11H, aaH, bbH, ccH, ddH, ssH,
ttH, uuH, vvH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H - 1FH, 7FH)
00H
model ID #1 (XV-5080)
10H
model ID #2 (XV-5080)
11H
commandID (RQ1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
ssH
size MSB
ttH
size
uuH
size
vvH
size LSB
sum
checksum
F7H
EOX (End Of Exclusive)
* The size of data that can be transmitted at one time is fixed for each type of data. And
data requests must be made with a fixed starting address and size. Refer to the address
and size given in "Parameter Address Map (p. 290)".
* For the checksum, refer to Example of an Exclusive message and calculating a
checksum (p. 303).
* Not received when the Receive Exclusive parameter (SYSTEM/COMMON) is OFF.
Data set 1DT1 (12H)
Status
Data byte
F0H
41H, dev, 00H, 10H, 12H, aaH, bbH, ccH, ddH,
eeH, ... ffH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H - 1FH, Initial value is 10H)
00H
Model ID #1 (XV-5080)
10H
Model ID #2 (XV-5080)
12H
Command ID (DT1)
aaH
Address MSB: upper byte of the starting address of the data to be sent
bbH
Address: upper middle byte of the starting address of the data to be
sent
ccH
Address: lower middle byte of the starting address of the data to be
sent
ddH
Address LSB: lower byte of the starting address of the data to be sent.
eeH
Data: the actual data to be sent. Multiple bytes of data are transmitted
in order starting from the address.
:
:
ffH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the
Address and Size given in Section 3, "Parameter address map.
288
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Not received when the Receive Exclusive parameter (SYSTEM/COMMON) is OFF.
Status
F0H
Byte
F0H
41H
dev
42H
12H
aaH
transmitted data
bbH
transmitted data
ccH
Status
transmitted data
F7H
ddH
of data are transmitted starting from the address.
:
eeH
sum
F7H
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the
Address and Size given in Section 3, "Parameter address map.
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to p. 303 .
* Not received when the Receive Exclusive parameter (SYSTEM/COMMON) is OFF.
2. Data transmission
section)
Channel Voice Messages
When execute the GM Data Transfer, the following Program Change and Control Change
will transmit.

Control Change

Bank Select (Controller number 0, 32)
Status
BnH
BnH
Status
n = MIDI channel number:0H - FH (Ch.1 - 16)
F7H
mm, ll = Bank nunber:00 00H - 7F 7FH (bank.1 - bank.16384)
Portamento Time (Controller number 5)
Status
BnH
n = MIDI channel number:0H - FH (Ch.1 - 16)
vv = Portamento Time:00H - 7FH (0 - 127)
Data Entry (Controller number 6, 38)
Status
BnH
BnH
n = MIDI channel number: 0H - FH (Ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB
Volume (Controller number 7)
Status
BnH
n = MIDI channel number:0H - FH (Ch.1 - 16)
vv = Volume:
Data byte
41H, dev, 42H, 12H, aaH, bbH, ccH, ddH, ... eeH, sum
Explanation
Exclusive status
ID number (Roland)
Device ID (dev: 10H)
Model ID
(GS)
Command ID
(DT1)
Address MSB:
upper byte of the starting address of the
Address:
middle byte of the starting address of the
Address LSB:
lower byte of the starting address of the
Data:
the actual data to be transmitted. Multiple bytes
:
Data
Checksum
EOX
(End Of Exclusive)
(sound source
2nd byte
3rd byte
00H
mmH
20H
llH
2nd byte
3rd byte
05H
vvH
2nd byte
3rd byte
06H
mmH
26H
llH
2nd byte
3rd byte
07H
vvH
00H - 7FH (0 - 127)
Status
F7H