USB Download

USB Download
The system can store 250,000 entries in its logs and
adds a new entry every 15 seconds. This means the
system stores 655 hours of system operation data, or 27
days of around-the-clock operation. Once full, th system
will overwrite the oldest data.
NOTE: To prevent losing any data, never go more than
27 days without downloading the logs.

Download Procedure

Uploading an edited system configuration file can dam-
age the system. Never put a modified SETTINGS.TXT
file in the UPLOAD folder on the flash drive.
1. Insert USB flash drive into USB port.
NOTE: Flash drive must be 8 GB or smaller.
2. The menu bar and USB indicator lights indicate that
the USB is downloading files. Wait for USB activity
to complete. A pop-up will be present until the trans-
fer is complete if it is not acknowledged.
NOTE: If the pop-up screen does not appear, the
flash drive is not compatible with the ADM. Try a dif-
ferent flash drive.
NOTE: The system can log up to 45 MB of addi-
tional data per week depending on system opera-
tion.
50
NOTICE
USB
ti31550a

Accessing Files

All files downloaded from the USB are put in a DOWN-
LOAD folder on the stick drive. For example:
"E:\GRACO\12345678\DOWNLOAD\". The 8-digit
numeric folder name matches the 8-digit ADM serial
number, which is located on the back of the ADM. When
downloading from multiple ADMs, there will be one
sub-folder in the GRACO folder for each ADM.
The log files should be opened in a spreadsheet pro-
gram.
NOTE: If emailing the files, zip (compress them to mini-
mize file size.

USB Logs

During operation, InvisiPac stores system and perfor-
mance related information to memory in the form of log
files. InvisiPac maintains the events, data, GCA, black
box, and diagnostics logs. Follow the Download Proce-
dure to retrieve log files.
Events Log
The event log (1-EVENT.CSV) maintains a record of the
last 175,000 events. Each event record in the log file
contains the date and time the event occurred, the event
type, event code, and event description.
Data Log
The data log (2-DATA.CSV) tracks the setpoint and
actual temperatures every 15 seconds. This log can
store up to 250,000 lines of data. The system stores
1041 hours of system operation data, or 43 days of
around-the-clock operation. Once full, the system will
overwrite the oldest data.
NOTE: To prevent losing any data, never go more than
43 days without downloading the logs.
GCA Log
This log (3-GCA.CSV) lists the installed GCA modules
and their respective software versions.
Black Box, Diagnostic Logs
These logs (4-BLACKB.CSV, 5-DIAGN.CSV) are
designed to provide useful information to Graco when
calling for technical assistance.