Installation - External Models
Integrate with InvisiPac (HM25 or HM50)
1. Set pattern control system type selector switch to 0.
NOTE: The system must be powered off for a
change in system type to have an effect.
2. Disconnect the CAN cable from the ADM (D), push
the cable through the plastic shroud (B), the remove
the shroud from the system.
3. Connect the CAN cable from the ADM (D) to one of
the male ends of the splitter (2).
4. Connect the CAN cable from the pattern controller
(A) to the other male end of the splitter (2).
5. Connect the male end of the short CAN cable con-
tained in pattern controller kit (3) to the female end
of the splitter.
6. Push the free end of the short CAN cable (3)
through the shroud and connect the female end to
the ADM.
7. Use zip ties (4) to attach the CAN cable bundle to
the other vertical bundle of cables.
16
Stand Alone
1. Set the pattern control system type selector switch
to 1.
NOTE: The system must be powered off for a
change in system type to have an effect.
2. Mount the ADM using the provided bracket
3. Connect the CAN cable (C) between the pattern
controller and the ADM

Connect Pattern Control Board

See Wire Pattern Control Board, page 18.
1. Install triggers and valves
2. Install PLC inputs and outputs (optional)
3. Install encoder (PC-8e only)
4. Install run up (optional, PC-8e only)