Screens
Run Up Control (Screens 6-7, PC-8e only)
Enter run up output settings. See Calibration - Run Up Control, page 34.
A - Enter screen
B - Minimum output
C - Maximum output
D - High calibration point
E - Low calibration point
P - Screen number (Screen 6)
Icon
Name
Output pressure
percentage
Line speed
Run up pressure
to line speed
curve
NOTE: % output refers to the percentage of the run up controller full scale setting, not the percentage of the inlet high
pressure.
34
A
B
Description
Enter minimum and maximum pressure for run up control.
Enter corresponding pressure points for entered line speed points to set run up curve.
Upper and lower line speed points
Curve is set by two points which are defined by the user. Upper and lower limits
define bounds over which run-up will function linearly.
C
D
P
E
334784G