Connect Electrical Cord

Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
National, State, and Local safety and fire codes.
The equipment must be grounded to reduce the
risk of electric shock. Improper grounding can
cause electric shock. Grounding provides an
escape wire for the electric current.
The pattern controller system is equipped with a ground
terminal. Have a qualified electrician ground the system
using this terminal.
Electrical power enters through the smaller cord grip on
the right side of the enclosure (see figure). The power
cord can be further secured inside the enclosure with
the provided zip-tie and tie mount.
1. Install power wires (L1/L2 or L/N) into terminals 2
and 4 on the disconnect switch. The switch accepts
solid or stranded 12 AWG and 14 AWG wire. For
ratings, see Technical Specifications, page 64.
NOTE: The power switch housing can be removed
for easy wiring using the red tab on top of the
switch.
334784G
2. Connect earth ground to the grounding terminal.
3. Verify that the cord grip securely tightens around the
power cord. Use a wrench to tighten, if necessary.