Installation - Internal Models (HM25 and HM50)

Installation - Internal Models (HM25 and HM50)

Connect Pattern Control Board

1. Set pattern control system type selector switch to 0.
NOTE: The system must be powered off for a
change in system type to have an effect.
12
2. Remove cord grip assembly (T) from pattern control
board (S) and remove inserts. Inserts will grip tightly
on most M8 and M12 cables and will expand and
compress to accept cables larger than the apparent
hole size.
3. Install valve signal wires, trigger signal wires, PLC
wires (optional) and encoder and run up wires
(PC-8e only). See Wire Pattern Control Board,
page 18.
4. Route cables through the opening in the pattern
control board back panel as shown.
5. Apply cord grip inserts over cables and replace into
frame. Replace frame onto pattern control panel.
6. Remove excess slack from cables but do not pull
tight. Tighten cord grip frame on inserts to secure.
334784G