Graco InvisiPac HM25 Operation, Repair, And Parts page 29

Pattern controller
Hide thumbs Also See for InvisiPac HM25:
Table of Contents

Advertisement

Event Map (Screen 1)
Enter configuration settings for this pattern:
1. Assign trigger to each gun.
2. Enter gun trigger offset.
3. Enter minimum product length (if false trigger pickup is a concern).
4. Enable pattern mirroring.
5. Enter stitch percentage and interval.
A - Enter screen
B - Gun number
C - Trigger for gun
D - Gun trigger offset
E - Minimum product length
F - Current program*
G - Stitch interval
H - Stitch savings
J - Mirror mode
P - Screen number (Screen 1)
Icon
Name
Trigger
Gun trigger offset
Minimum product length Blocks triggers from activating a second pattern within the minimum product
Mirror mode
Stitch savings
Stitch interval
* Current program indicator signifies that changes to the settings on this page will only affect the current program.
334784G
A
B
C
D
E
Trigger associated with this gun
The physical distance or time between the trigger and the gun
length
Mirrors beads from the leading edge of the box to the trailing edge of the box.
NOTE: If mirror mode is selected, the gun-to-trigger offset must be at least half
the length of the box. See Mirror Mode, page 39.
Percentage of glue saved by stitching. Set to 0 to disable stitching. NOTE: Stitch-
ing must also be enabled/disabled for each bead. See Stitching, page 37.
The distance between the start of each stitch
Description
Screens
F
G
P
H
J
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invisipac hm25cInvisipac hm50

Table of Contents