Wire Pattern Control Board

Encoder Installation

(PC-8e only)

1. Connect up to two encoders to monitor line speed.
NOTE: Line 1 and line 2 on the ADM.
NOTE: Encoder type must be quadrature differential
line driver (RS422). Scaling is entered in the
encoder setup screen using the live calibration fea-
ture.
NOTE: Some encoders have Z and Z' connections.
These are not used and do not need to be con-
nected.
NOTE: Encoder direction can be reversed by swap-
ping A and A' with B and B'. Do this is the line speed
reads negative on the ADM.
Graco Encoder Wiring Diagram
Terminal
Function
Plus
15V Supply
A
Phase A signal
(RS422)
A'
Phase A signal return White
B
Phase B signal
(RS422)
B'
Phase B signal return Green
Minus (-)
Return
PE
Shield
20

Run Up Installation (PC-8e only)

1. Connect up to two "I/P" or "V/P" run-up air pressure
Terminal
Plus (+)
%
Minus (-)
Minus (-)
Wire Color
Red
Brown
Yellow
Blue
Bare
regulators to vary pump pressure based on line
speed. Hardware automatically detects whether an
I2P or V2P is connected.
NOTE: Pressure vs. line speed settings are entered
on the run-up setup screen. See Run Up Control,
page 42.
Standard Wire Colors
Function
24V Supply
Output to run-up
Return
Return
M12 Cable
Brown
Black
Blue
White
334784G