Wire Pattern Control Board; Valve Installation; Trigger Installation - Graco InvisiPac HM25 Operation, Repair, And Parts

Pattern controller
Hide thumbs Also See for InvisiPac HM25:
Table of Contents

Advertisement

Wire Pattern Control Board

Wire Pattern Control Board

Valve Installation

1. Connect up to 8 valves.
NOTE: Control voltage is 24 VDC with a limit of 1
amp per output and 6 amps total.
NOTE: Green LEDs indicate the status of each
valve.
NOTE: DIN cable black wires are labeled 1 and 2. 1
is plus and 2 is minus.
Standard Wiring Colors
Terminal
Function
Cable
Plus (+)
24V Supply
Minus (-)
Return
18
M8
DIN Cable
Cable
Brown
Black 1
Blue
Black 2

Trigger Installation

1. Connect up to 4 NPN, PNP, or dry contact triggers.
NOTE: Supplied voltage (+) is 24 VDC
2. Connect the two wires between TR and minus (-) to
install a dry contact.
NOTE: Yellow LEDs indicate the status of each trig-
ger. Polarity can be inverted if needed. See Trigger
Setup, page 31.
Standard Wiring Colors
Terminal
Function
Plus (+)
24V Supply
TR
NPN, PNP, or dry con-
tact
Minus (-)
Return (or dry contact) Blue
M8 or M12
Cable
Brown
Black or white
334784G