9. Return the pressure on the InvisiPac pump pressure
gauge to the position from step 3.
10. Enable the pressure compensation.

Modulated Bead (PC-8e Only)

Modulated bead is used to adjust fluid output according
to line speed without a pressure regulator (using stitch-
ing).
NOTE: Modulated beads use the same stitch interval as
a normal stitched bead. See Event Map, page 29.
1. Enable modulated bead.
2. Enter "100" for both high and output values.
334784G
NOTE: A value of "100" will ensure that a solid bead
is dispensed at speeds above maximum line speed.
3. Enter the minimum and maximum line speed.
NOTE: The maximum line speed is the speed at
which beads will go from solid to stitched.
4. Enter the low output values.
Minimum Speed
Low Output =
Maximum Speed
Calibration
* 100
43