Siemens Sinamics S120 Function Manual page 680

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Communication
10.4 Communication via SINAMICS Link
2. Specify the slots in the input buffer (p8870) in which the PZDs from the telegrams are to
3. After transfer, the data from the telegrams of the nodes 2 and 3, should be copied via
Table 10- 73 Receive data for node 1
Sender
p8872[x]
Node
For node 2, define the sender of the receive data:
1. You can determine from which node you wish to receive data:
2. Specify the slots in the input buffer (p8870), in which the PZDs from the telegrams should
3. After transfer, the data from the telegram of the node 1, should be copied via p8870 into
678
be stored:
PZD 1 in p8870[0] = 1 (PZD 1 from telegram 2)
PZD 1 in p8870[1] = 2 (PZD 1 from telegram 3)
PZD 2 in p8870[2] = 3 (PZD 2 from telegram 2, first part of p2061[1])
PZD 3 in p8870[3] = 3 (PZD 3 from telegram 2, second part of p2061 [1])
PZD 2 in p8870[4] = 4 (PZD 2 from telegram 3, first part of p2061[1])
PZD 3 in p8870[5] = 5 (PZD 3 from telegram 3, second part of p2061[1])
PZD 4 in p8870[6] = 6 (PZD 4 from telegram 2, first part of p2061[3])
PZD 5 in p8870[7] = 7 (PZD 5 from telegram 2, second part of p2061[3])
PZD 4 in p8870[4] = 8 (PZD 4 from telegram 3, first part of p2061[1])
PZD 5 in p8870[5] = 9 (PZD 5 from telegram 3, second part of p2061[1])
The remaining PZDs remain empty.
p8870 into parameters r2050 [x] and r2060 [x].
Receive
buffer
p8870[x]
x
2
1
PZD 1
3
2
PZD 2
2
3
PZD 3
2
4
PZD 4
3
5
PZD 5
3
6
PZD 6
2
7
PZD 7
2
8
PZD 8
3
9
PZD 9
3
10
PZD 10
0
...
...
0
16
PZD 16
PZD 1 from telegram 1: p8872[0] = 1
PZD 2 from telegram 1: p8872[1] = 1
PZD 3 from telegram 1: p8872[2] = 1
be saved:
PZD 1 in p8870[0] = 1 (PZD 1 from telegram 1)
PZD 2 in p8870[1] = 2 (PZD 1 from telegram 1, first part of p2061[1])
PZD 3 in p8870[2] = 3 (PZD 2, from telegram 1, second part of p2061[1])
parameters r2050 [x] and r2060 [x].
Transfer to
Transfer to
p2050[x]
p2060[x]
0
-
1
-
-
2
-
-
4
-
-
6
-
-
8
-
...
...
15
-
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Parameter
Contents
r0899
ZSW1_
r0899
ZSW1_
r0021
n_act_
n_act_
r0021
n_act_
n_act_
r0031
m_act_
m_act_
r0031
m_act_
m_act_
0
Empty
0
Empty
T2
T3
T2_a
T2_b
T3_a
T3_b
T2_a
T2_b
T3_a
T3_b
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents