Siemens Sinamics S120 Function Manual page 542

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Communication
10.1 Communication according to PROFIdrive
Bit
Meaning
7
Alarm active
8
Speed
setpoint-actual value deviation
within the tolerance band
9
Control request to PLC
10
f or n comparison value reached or
exceeded
Note:
The message is parameterized as follows:
p2141 Threshold value
p2142 Hysteresis
11
I, M or P limit reached or exceeded
12
Holding brake open
13
No motor overtemperature alarm
14
Reserved
15
Reserved
ZSW2_BM (status word 2, metal industry)
See function diagram [2429].
Table 10- 27 Description of ZSW2_BM (status word 2, metal industry)
Bit
Meaning
0
Reserved
1
Reserved
2
Reserved
540
Remarks
1
Alarm active
The drive is operational again. No
acknowledgement necessary.
The active alarms are stored in the alarm buffer.
0
No alarm active
No active alarm in the alarm buffer.
1
Setpoint/actual value monitoring within tolerance
band
Actual value within a tolerance band; dynamic
overshoot or undershoot for t < t
e.g.
n = n
±
set
f = f
±, etc.,
set
t
can be parameterized
max
0
Setpoint/actual value monitoring not within
tolerance band
1
Control requested
The PLC is requested to assume control. Condition
for applications with isochronous mode: Drive
synchronized with PLC system.
0
Local operation
Control only possible on device
1
f or n comparison value reached or exceeded.
0
f or n comparison value not reached.
1
I, M or P limit not reached
0
I, M or P limit reached or exceeded
1
Holding brake opened
0
Holding brake closed
1
Motor overtemperature alarm not active
0
Motor overtemperature alarm active
-
-
-
-
Remarks
-
-
-
-
-
-
permissible,
max
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Parameter
BO: r2139.7
BO: r2197.7
BO: r0899.9
BO: r2199.1
BO: r1407.7
BO: r0899.12
BO: r2135.14
-
-
Parameter
-
-
-
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents