Communication
10.1 Communication according to PROFIdrive
Bit
Meaning
13
Pulses enabled
Application:
Armature short-circuit protection must only be switched on when the pulses are inhibited.
This signal can be evaluated as one of many conditions when armature short-circuit protection is activated.
14.15 Reserved
MELD_NAMUR
Display of the NAMUR message bit bar.
AKTSATZ
See function diagram [3650].
Table 10- 30 Description of AKTSATZ (active traversing block/MDI active)
Bit
Meaning
0
Active traversing block, bit 0
1
Active traversing block, bit 1
2
Active traversing block, bit 2
3
Active traversing block, bit 3
4
Active traversing block, bit 4
5
Active traversing block, bit 5
6 ... 14
Reserved
15
MDI active
POS_ZSW
See function diagram [3645].
Table 10- 31 Description of POS_ZSW (status word, positioning mode)
Bit
Meaning
0
Tracking mode active
1
Velocity limiting active
2
Setpoint static
3
Position setpoint reached
546
Remarks
1
Pulses enabled
The pulses for activating the motor are enabled.
0
Pulses inhibited
-
-
Remarks
Active traversing block (6-bit counter)
1
MDI active
0
MDI not active
Remarks
1
Tracking mode active
0
Tracking mode not active
1
Active
0
Not active
1
Setpoint static
0
Setpoint not static
1
Position setpoint reached
0
Position setpoint not reached
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Parameter
BO: r0899.11
-
Parameter
BO: r2670.0
BO: r2670.1
BO: r2670.2
BO: r2670.3
BO: r2670.4
BO: r2670.5
BO: r2670.15
Parameter
BO: r2683.0
BO: r2683.1
BO: r2683.2
BO: r2683.3
Drive functions