HEIDENHAIN iTNC 530 Service Manual page 50

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Error message
Label 0 is missing
Label number not
found
Label number not
found
Label number %-3u
already assigned
Label number
already assigned
Pos. deviation too
large %.1s
Position error:
Center in axis 1
Position error:
Center in axis 2
Pos. contr. cyc.
time error
Position control
time too short
Language load
error XX
Interrupt running
transmission?
Drive not found
LBL CALL not
permitted
Power supply unit
%.1s is not ready
Power stage %.1s:
I max incorrect
Power stage %.1s:
U-Imax incorrect
2 – 48
Error
Cause of error
number
363
A contour subprogram defined in
Cycle 14 (Contour Geometry, ISO:
G37) is not concluded with LBL 0
(ISO: G98).
362
In Cycle 14 (contour geometry, ISO:
G37) you defined a subprogram
number that does not exist.
364
You attempted to use LBL CALL
(ISO: L x,x) to call a subprogram or a
program section repeat that does
not exist.
188
During a program start or a
subprogram call, several LBL SET
(ISO: G98 Lxx) blocks with the
same label number were found.
187
You attempted to program the
same label number in several LBL
SET (ISO: G98 Lxx) blocks in a part
program.
2944
MP640 too small.
Incorrect mounting of position
encoder.
Incorrect temperature
compensation, linear or nonlinear
compensation, or reversal error.
2506
Probing cycle for workpiece
measurement: Center of 1st axis
outside of position tolerance.
2507
Probing cycle for workpiece
measurement: Center of 2nd axis
outside of position tolerance.
2854
MCU is outputting erroneous cycle
time for CCU position controller.
Hardware error.
2828
The time frame for the position
controller is too small. It can be
increased in MP7600.0.
2210
You attempted to start a data
transfer, although the interface is
already occupied.
1901
The NFS server cannot find the
drive that you selected.
269
A subprogram call (LBL CALL, ISO:
Lx,x) has been programmed in a
program being run blockwise from
an external data medium.
2318
The readiness signal for the power
supply module was switched off
during operation.
2193
IMAX of the power stage for the
displayed axis is incorrect
IMAX = peak current
2192
U-IMAX of the power stage for the
displayed axis is incorrect
U-IMAX = voltage of the current
sensor
Corrective action
Conclude the contour subprogram
with LBL 0 (ISO: G98).
Correct the subprogram number in
Cycle 14.
Enter the missing subprogram.
Change the number in the LBL
CALL block.
Insert a subprogram or program
section repeat.
Edit the part program.
Edit the part program.
Inform your service agency.
Correct MP640.
Check the encoder mounting.
Check the compensation.
Check the workpiece, and if
necessary the measuring log.
Check the workpiece, and if
necessary the measuring log.
Inform your service agency.
Check machine parameter 7600.x.
Exchange drive control board.
Increase the input value in
MP7600.0 by 1.
Inform your service agency.
Reply with YES to interrupt the
transmission now running. Reply
with NO to allow it to continue.
Check whether your network is
active.
Delete the sub program call.
Inform your service agency.
Inform your service agency.
Inform your service agency.