25.1.7 Integral PLC

MP
MP4000.0-15
MP4020
MP4030
MP4030.0
MP4030.1
MP4030.2
MP4030.3
MP4050.0-8
MP4070
MP4110.0-47
MP4111.96-x
July 2002
Function and input
Options for the conditional compilation of the PLC program
PLC Functions
Format:
%xxxxxxxxxxxxx
Input:
Bit 0 to bit 4: Reserved
Bit 5: Single or double spindle operation
0: Single-spindle operation
1: Double-spindle operation
Bit 6 - Reserved
Bit 7 - Transfer the values of the Pt 100 inputs
0: Accept values at a change rate of 1 K/s.
1: Accept results immediately
Bit 8 - Behavior after an ext. emergency stop
0: "Approach position" is not automatically
activated
1: "Approach position" is automatically activated
Bit 9 - Behavior of a simulated key
0: Simulated key is transferred immediately to
the NC
1: Simulated key is processed first by an active
PLC window before being transferred to the NC
Bit 10 - Behavior of a locked key
0: Locked key only works on the active PLC
window
1: Locked key works on neither the active PLC
window nor on the NC
Bit 11 – PLC counter in MP4120.x
0: Input in PLC cycles
1: Input in seconds
Bit 12 - Font size in PLC window
0: Automatic adaptation of font size to screen
1: Font size for BF 120
Assignment of physical to logical PL
Input:
0: First logical PL
1: Second logical PL
2: Third logical PL
3: Fourth logical PL
First physical PL
Second physical PL
Third physical PL
Fourth physical PL
Traverse distance for lubrication of axes 1 to 9
Input:
0 to 99 999.999 [m/s]
Compensation amount per PLC cycle for lagged-tracking
axis error compensation
Input:
0.0001 to 0.005 [mm]
Run time PLC timer T0 to T47
Input:
0 to 1,000,000.000 [s]
Run time PLC timer T96 to x (defined in OEM.SYS)
Input:
0 to 1,000,000.000 [s]
Software
version and
behavior
RESET
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
25 – 317