Error message
Path comp
incorrectly begun:
NC block must be a
line
Path comp wrongly
ended:NC block
must be a line
Band-pass
parameter %.2s
Baud rate not
possible
Calculated rpm too
large
Calculated error no.
too large
Calculated
coordinate too large
Calculated label no.
too large
Calculated tool
number too large
Calc. scaling factor
too large
Calculated
Q-parameter too
large
Calculated feed rate
too large
Range exceeded
Trav. range shift not
permitted
Enter Q247 greater
than 5
July 2002
Error
Cause of error
number
515
You attempted to begin a tool
radius compensation on a circular
path.
516
You attempted to end a tool radius
compensation on a circular path.
2913
Incorrect entry in MP2540,
MP2541, MP2550 or MP2551
Internal software error
197
The baud rates set at the two data
interfaces do not permit
simultaneous transmission over
both interfaces.
218
Calculation of a spindle speed from
a Q parameter resulted in a value
that was outside the permissible
range of 0 to +99 999.9999.
222
Calculation of an error number for
the function FN14 (ISO: D14) from a
Q parameter resulted in a value that
was outside the permissible range
of 0 to 499.
217
Calculation of a coordinate from a Q
parameter resulted in a value that
was outside the permissible range
of -99 999.9999 to +99 999.9999.
221
Calculation of a label number from a
Q parameter resulted in a value that
was outside the permissible range
of 1 to 255.
220
Calculation of a tool number from a
Q parameter resulted in a value that
was outside the permissible range
of 0 to 32767.
You have called a tool number
which is greater than the number of
tools defined in the tool table.
223
Calculation of a scaling factor from a
Q parameter resulted in a value that
was outside the permissible range
of 0.0001 to 100.007936.
216
The TNC tried to display a
Q parameter, whose value was
outside the permissible range of
–99 999.9999 to +99 999.9999.
219
Calculation of a feed rate from a
Q parameter resulted in a value that
was outside the permissible range
of 0 to 300 000.
443
During digitizing the stylus went
outside the defined digitizing range.
2996
During a return to the contour, the
PLC commanded an illegal traverse
range shift.
2830
In a measuring cycle, you entered in
parameter Q247 an angular step
smaller than 5 degrees.
Corrective action
Tool radius compensation can only
be activated with a line.
Tool radius compensation can only
be canceled with a line block.
Inform your service agency.
Check entry in MP2540, MP2541,
MP2550 and MP2551
Check software version
Select another baud rate.
Edit the part program.
Edit the part program.
Edit the part program.
Edit the part program.
Edit the part program.
Edit the part program.
Edit the part program.
Edit the part program.
Check the data in the Range cycle,
in particular the entry for the touch
probe axis.
If the error recurs: Have the
machine manufacturer change the
PLC program.
To ensure sufficient measuring
accuracy, enter in Q247 an angular
step greater than 5 degrees.
2 – 23