7.5.2 Interface card Id.Nr. 31 437-xx

Overview
LEDs and
connectors
Pin layout
see "X51 to X62: PWM output" on page 122
X111, X112
Connection to iTNC
Description of LEDs
LED
READY
(green)
SH1 (red)
(X111/
X112)
SH2 (red)
(X111/
X112)
July 2002
Designation
Operating element
X73
Enabling connector
Equipment ground
SH1
Pulse release disabled (red)
SH2
Pulse release disabled (red)
READY
Ready for operation (green)
SH1
Pulse release disabled (red)
SH2
Pulse release disabled (red)
X111
PWM, axis/spindle
X112
PWM, axis/spindle
X351
SIMODRIVE unit bus
Condition
Meaning/Possible causes of error
LED On
Axis 1 and axis 2 are ready for operation.
(operating state)
MCU acknowledges readiness (both SH1 LEDs are Off)
LED Off (error)
The safety relay did not respond.
(Is 24 V power supply available at X73/3)?
RESET (+24 V) from unit bus?
Controller pulse inhibit (+15 V) from unit bus?
P5 (+5 V) does not exist?
LED On (error)
MCU acknowledges error in readiness.
(X111/X112-SH1 pin 5a low)
LED usually off
No controller enable for axis by MC.
With PLC module 9161, the iTNC sets the axis-specific
internal current and speed controller
(X111/X112 pin 4a high).
Speed and current controller are not active?
Clamping axis clamped?
No M function active for spindle?