HEIDENHAIN iTNC 530 Service Manual page 43

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Error message
Incorrect
compensation
values
Program data
erroneous
Program data
erroneous
Incorrect tool data
Faulty braking
process %.2s
Field name not
found
Field current error
%.2s
Field angle error
%.2s
Window cannot be
shifted further
Window too large
Window too small
FK: Arithmetical
error
FK reference to
current block
Parallel operation of
FK graphics not
possible
FK block not
permitted at this
point
July 2002
Error
Cause of error
number
2373
Erroneous data in compensation
table.
945
This is a general error message
which informs that there is some
error in the program data (e.g.
ERROR block).
946
A syntax error occurred during
downloading via the data interface.
The TNC marks the erroneous block
with ERROR.
2374
Erroneous data in tool table.
2827
The braking process was not
started or it was started after a
delay.
2224
In the definition of a freely definable
table you used a field name that is
not an element of the table.
2897
Incorrect entry in motor table.
2909
Incorrect entry in MP2340 or
MP2350.
530
In a programming graphic
simulation you moved the selection
frame to the edge of the window
which calls for a reduction of scale
beyond the capability of the
graphics controller.
528
Programming graphics: During
reduction of a programming graphic
simulation the window section
exceeds the limits of the graphics
processor.
529
During enlargement of a
programming graphic simulation
the window section does not reach
the limits of the graphics processor.
518
FK programming: Arithmetical error
in calculation of a FK contour (e.g.
division by 0, root of a negative
number).
212
You attempted in an FK program to
delete a block to which another part
of the program makes a reference.
526
FK programming: You attempted to
start an FK graphic while the iTNC
was already running a part program.
519
FK programming: An FK positioning
block (FL,FC,FLT, FCT) can follow a
conventional positioning block only if
the end point of the conventional
positioning block is unambiguously
defined, i.e.:
The conventional positioning block
must not contain any Q parameters.
The first FK block must not follow a
label.
Corrective action
Inform your service agency.
Edit the part program.
Edit the part program.
Inform your service agency.
Switch the control voltage off and
on again, or inform your service
agency.
The table definition must be
changed. Contact your machine
tool builder.
Inform your service agency.
Check the motor table.
Inform your service agency.
Check entry in MP2340 / MP2350
Keep the selection frame within
the window.
Enlarge the programming graphic.
Reduce the programming graphic.
Check the input in the FK section.
Change FK reference.
Start FK graphic after part program
has been run.
Edit the part program.