Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

25.1.9 3-D touch probe

MP
MP6010
MP6120
MP6130
MP6140
MP6150
MP6160
MP6161
MP6162
MP6163
MP6165
MP6170
MP6171
25 – 320
Function and input
Selection of the touch probe
Input:
0: Touch probe with cable transmission
1: Touch probe with infrared transmission
Probing feed rate (triggering touch probe)
Input:
1 to 3000 [mm/min]
Maximum measuring range
Input:
0.001 to 99,999.9999 [mm]
Setup clearance over measuring point
Input:
0.001 to 99,999.9999 [mm]
Rapid traverse in probing cycle (triggering touch probe)
Input:
10 to 20,000 [mm/min]
M function for probing from opposite directions
Input:
-1: Spindle orientation directly by NC
0: Function inactive
1 to 999: Number of the M function for spindle
orientation through PLC
M function for orienting the touch probe before every
measuring process
Input:
-1: Spindle orientation directly by the NC
0: Function inactive
1 to 999: Number of the M function
Orientation angle
Input:
0 to 359.9999 [°]
Minimum difference between the current spindle angle and
MP6162 before executing an oriented spindle stop
Input:
0 to 3.0000 [°]
Orient the probe before approaching with Cycle 0 or 1, or
with manual probing
Input:
0: Probe is not oriented before each probing
1: Probe is oriented and always deflected in the
same direction
Number of measurements in a programmed measurement
(touch probe block)
Input:
1 to 3
Confidence range for programmed measurement
(MP6170 > 1)
Input:
0.002 to 0.999 [mm]
Software
version and
behavior
PLC
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
HEIDENHAIN Service Manual iTNC 530

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents