HEIDENHAIN iTNC 530 Service Manual page 37

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Error message
Incorrect entry in
MP%.4u.%u
Incorrect entry in
MP%u
Incorrect gear
range
Incorrect datum
number
Incorrect number
for FN17/FN18
Wrong pocket
number
Wrong pocket
number
Incorrect reference
position %.1s
Incorret reference
position %.2s
Wrong axis for
column
Wrong angular axis 1794
Wrong axis for line
Wrong Range cycle 1790
Incorrect file type
Incorrect NC block
in cycle
July 2002
Error
Cause of error
number
1182
An incorrect value was entered in a
machine parameter.
2746
Input value of the machine
parameter MP2180 (PWM
frequency) is incorrect.
2934
Software error
2039
You have called a datum number
that does not exist in the active
datum table.
1749
The number combination of the
system datum (FN17/FN18, ISO:
D17/D18) is not allowed.
160
The input number of the pocket
number in the tool table is greater
than machine parameter MP7261.
MP7261 = 0, pocket output is
activated through MP7480 and no
pocket has been assigned to the
called tool.
937
The input number of the pocket
number in the tool table is greater
than machine parameter MP7261.
MP7261 = 0, pocket output is
activated through MP7480 and no
pocket has been assigned to the
called tool.
2745
1) Signal of the reference pulse is
disturbed (ground shield).
2) Position determination via
Z1-track is defective.
3) Incorrect encoder line count.
2922
Incorrect motor selected (MP2200).
Grounding error on motor encoder
cable (disturbance on reference
signal line).
Motor encoder defective.
1793
Digitizing with measuring touch
probe: In the Meander or Contour
Lines cycle you defined a rotary axis
as column axis.
During digitizing with rotary axes,
the rotary axis is not parallel to the
line axis or the column axis.
1792
During a Meander or Contour Line
cycle, the line axis is the same as
the probe axis
There is no line axis in the range
definition (RANGE cycle).
Cycle 15 RANGE is active at the
start of a Contour Line cycle.
2223
You searched for a table that does
not have the file extension .TAB.
273
A part program stored in an EPROM
contains a jump to a label (LBL
CALL) indicating a jump counter.
Corrective action
Edit your entry.
Edit MP2180: PWM frequency.
Inform your service agency.
Check software version.
Call another datum number or
activate another datum table.
Check the number and index of the
system datum.
Check the tool pocket table.
Inform your service agency.
Check the tool pocket table.
Inform your service agency.
1) Take measures for noise
suppression.
2) Inform your service agency.
3) Inform your service agency;
take measures for noise
suppression; check motor table.
Inform your service agency.
Check the motor selection
(MP2200).
Check cabling of the motor encoder
(grounding).
Exchange the motor.
In the Meander or Contour Lines
cycle, define a linear axis as column
axis.
Check the axis definitions in the
Range, Meander, Contour Lines
and Line cycles.
Check the axes defined in the
RANGE cycle.
Use the Contour Lines cycle only in
connection with Cycle 5 RANGE.
Search only for tables with
extension .TAB.
Edit the user cycle.
2 – 35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents