HEIDENHAIN iTNC 530 Service Manual page 307

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

MP
MP812
MP850.x
MP855.x
MP860.x
MP910.x
MP911.x
MP912.x
MP920.x
MP921.x
MP922.x
MP950.x
MP951.x
MP960.x
July 2002
Function and input
Activate software limit switches for tilting axes with
modulo display, M94 and encoders with EnDat interface
Format:
%xxxxxxxxxxxxxx
Input:
Bits 0 to 3 correspond to axes 1 to 14:
0: Software limit switch not active
1: Software limit switch active
Synchronized axes
Input:
0: Master axis
1: Slave axis to axis 1
2: Slave axis to axis 2
3: Slave axis to axis 3
4: Slave axis to axis 4
5: Slave axis to axis 5
6: Slave axis to axis 6
7: Slave axis to axis 7
8: Slave axis to axis 8
9: Slave axis to axis 9
Sychronization monitoring
Input:
0 to 100.0000 [mm]
0: Monitoring not active
Datum for synchronous control
Input:
0: Datum at position after switch-on
1: Datum at reference marks
2: Axis is torque slave axis
Positive software limit switches, traverse range 1 (default
setting after power on)
Input:
-99,999.9999 to +99,999 [mm] or [°]
Positive software limit switches, traverse range 2
Input:
-99,999.9999 to +99,999 [mm] or [°]
Positive software limit switches, traverse range 3
Input:
-99,999.9999 to +99,999 [mm] or [°]
Negative software limit switches, traverse range 1 (default
setting after power on)
Input:
-99,999.9999 to +99,999 [mm] or [°]
Negative software limit switches, traverse range 2
Input:
-99,999.9999 to +99,999 [mm] or [°]
Negative software limit switches, traverse range 3
Input:
-99,999.9999 to +99,999 [mm] or [°]
Datum for positioning blocks with M92 for axes 1 to 9
Input:
-99,999.9999 to +99,999.9999 [mm] or [°]
Values with respect to the machine datum
Simulated tool-change position for TOOL CALL during
mid-program startup (block scan)
Input:
-99,999.9999 to +99,999.9999 [mm] or [°]
Machine Datum
Input:
-99,999.9999 to +99 999.999 [mm] or [°]
Values with respect to the scale reference point
Software
version and
behavior
RESET
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
REF
25 – 305