18.2 Monitoring the PLC Inputs and Outputs

PLC inputs
When checking the PLC inputs, proceed as follows:
Switch off the main switch of the machine.
Connect the universal measuring adapter to connector X42 or X46 between the MC and
the connecting cable.
Switch the machine On again.
Press the following key combination:
The logic states for the inputs are displayed on the screen. These must be in agreement with
the voltage level for each input.
If, at correct input voltage, there is a difference between the logical condition and the voltage
level of an input, then the corresponding input board of the logic unit or the PL 405B/510B
I/O unit is defective.
18 – 252
Note
The voltage levels for the PLC inputs or the output current for the PLC outputs on the
PL 405B/410B must be measured directly at the corresponding terminal.
Select the Programming and Editing mode.
Prepare iTNC for entry of code number.
Confirm.
Call TABLE function.
Display table for inputs.
Press the END key twice to end the TABLE function and exit the Programming
and Editing mode.
Enter the code number.
HEIDENHAIN Service Manual iTNC 530