When Using Pwm Output Function - Panasonic FP0H User Manual

Control unit positioning/pwm output/high-speed counter
Hide thumbs Also See for FP0H:
Table of Contents

Advertisement

4.1.3 When Using PWM Output Function

• The following reserved areas are allocated to the PWM output and control active flag.
• Allocate them so that they do not overlap the I/O used for the pulse output function.
 Allocation of I/O signals
FP0H mode
Signal name
PWM output
Control active flag (BUSY)
FPΣ mode
Signal name
PWM output
Control active flag (BUSY)
REFERENCE
For details of the FPΣ mode, refer to "11. FPΣ Mode".
CH0
CH1
Y0
Y3
R911C
R911D
I/O number
CH0
CH2
Y0
Y3
R903A
R903C
4.1 Confirming I/O Allocation
I/O number
CH2
Y8
R911E
CH3
YB
R911F
4-7