Settings of Control Unit
4.1.2 When Using Pulse Output Function (FPΣ Compatible Instruction Mode)
• The following reserved areas are allocated to the home input and control active flag.
• Arbitrary inputs are allocated to the near home input and pulse output stop signal
(emergency stop).
 Allocation of I/O signals (Input)
FP0H mode
Signal name
Home input (Note1)
Near home input
Control active flag (BUSY)
Operation done
Home return done
FPΣ mode
Signal name
Home input (Note1)
Near home input
Control active flag (BUSY)
Operation done
Home return done
(Note 1): Even when setting the linear interpolation, the interpolation operation is not performed for the home return.
Execute the operation for X axes and Y axes separately.
(Note 2): The near home input will be enabled by allocating an arbitrary input and turning on the bit 4 of the special
data register DT90052 by the pulse output control instruction (F0).
(Note 3): The falling edge (on to off) of the control flag (BUSY) after the execution of the pulse output instruction
(F171) is used in place of the operation done flag or home return done flag.
4-4
I/O number
Axis 1
Axis 2
CH0
CH1
X2
X5
R911C
R911D
I/O number
Axis 1
Axis 2
CH0
CH2
X2
X5
(Note 2)
903A
903C
(Note 3)
Axis 3
CH2
X6
(Note 2)
R911E
(Note 3)
Axis 4
CH3
X7
R911F