Precautions for Safe Use
● Handling
Do not drop the G9SP-series Controller or subject it to excessive vibration or mechanical shock. The
G9SP-series Controller may be damaged and may not function properly.
● Installation and Storage Environment
Do not use or store the G9SP-series Controller in any of the following locations:
Take appropriate and sufficient measures when installing systems in the following locations. Inappropri-
ate and insufficient measures may result in malfunction.
This is a class A product designed for use in industrial environments. In residential areas it may cause
radio interference, in which case the user may be required to take adequate measures to reduce interfer-
ence.
● Installation and Mounting
• Use the G9SP-series Controller within an enclosure with IP54 protection or higher according to IEC/
EN 60529.
• Use DIN Track (TH35-7.5/TH35-15 according to IEC 60715) or M4 screws with a tightening torque of
1.2 N·m (10.5 lb·in) to install the G9SP-series Controller into the control panel.
• Mount the G9SP-series Controller to the DIN Track using PFP-M End Plates (not included with the
G9SP-series Controller) to prevent it from falling off the DIN Track because of vibration. Correctly
mount all Units to DIN Track.
• Install the G9SP-series Controller in the vertical direction shown below to ensure adequate cooling.
• Space must be provided around the G9SP-series Controller, at least 20 mm from its side surfaces and
at least 50 mm from its top and bottom surfaces, for ventilation, wiring and Unit replacement.
• Be sure to lock all locking mechanisms, such as those on I/O terminal blocks and connectors, before
attempting to use the G9SP-series Controller.
xviii
• Locations subject to direct sunlight
• Locations subject to temperatures or humidity outside the range specified in the
specifications
• Locations subject to condensation as the result of severe changes in temperature
• Locations subject to corrosive or flammable gases
• Locations subject to dust (especially iron dust) or salts
• Locations subject to water, oil, or chemicals
• Locations subject to shock or vibration
• Locations subject to static electricity or other forms of noise
• Locations subject to strong electromagnetic fields
• Locations subject to possible exposure to radioactivity
• Locations close to power supplies