Rules For Wiring With Drive-Cliq; Binding Drive-Cliq Interconnection Rules - Siemens Sinamics s120 Commissioning Manual

With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

Preparation for commissioning
2.5 System rules, sampling times and DRIVE-CLiQ wiring
2.5.4

Rules for wiring with DRIVE-CLiQ

Rules apply for wiring components with DRIVE-CLiQ. A distinction is made between binding
DRIVE-CLiQ rules, which must be unconditionally observed and recommended rules, which
should then be maintained so that the topology, generated offline in the commissioning tool,
no longer has to be changed.
The maximum number of DRIVE-CLiQ components and the possible wiring type depend on
the following factors:
● The binding DRIVE-CLiQ wiring rules
● The number and type of activated drives and functions on the Control Unit in question
● The computing power of the Control Unit in question
● The set processing and communication cycles
Below you will find the binding wiring rules and some other recommendations as well as a
few sample topologies for DRIVE-CLiQ wiring.
The components used in these examples can be removed, replaced with others or
supplemented. If components are replaced by another type or additional components are
added, then the SIZER configuring tool should be used to check this topology.
If the actual topology does not match the topology created offline using the commissioning
tool, the offline topology must be changed accordingly before it is downloaded.
2.5.4.1

Binding DRIVE-CLiQ interconnection rules

The following generally binding DRIVE-CLiQ rules must be observed to ensure safe
operation of the drive.
● Only one Control Unit is permitted in the role of DRIVE-CLiQ master in a DRIVE-CLiQ
topology.
● A maximum of 14 DRIVE-CLiQ nodes can be connected to a Control Unit port on a
DRIVE-CLiQ line.
Note
One Double Motor Module, one DMC20, one DME20, one TM54F and one CUA32 each
correspond to two DRIVE-CLiQ nodes. This also applies to Double Motor Modules, at
which just one drive is configured.
● Ring wiring or double wiring of components is not permitted.
● Drive topologies with DRIVE-CLiQ components that are not supported (by the type and
the firmware version of the Control Unit) are not permitted.
48
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5

Advertisement

Table of Contents
loading

Table of Contents