Processing Pallet Table - HEIDENHAIN TNC 640 User Manual

Hide thumbs Also See for TNC 640:
Table of Contents

Advertisement

Pallet Management | Pallet management

Processing pallet table

A machine parameter defines whether the control is to
execute the pallet table blockwise or continuously.
You can execute a pallet table as follows:
Switch to Program run, full sequence or
Program run, single block operating mode
Press the PGM MGT key
If no pallet tables are visible:
Press the SELECT TYPE soft key
Press the SHOW ALL soft key
Select a pallet table with the arrow keys
Press the ENT key
Select the screen layout, if necessary
Execute with the NC Start key
To check the NC program content before execution, proceed as
follows:
Select pallet table
With the arrow keys, choose the NC program you would like to
check
Press the OPEN THE PROGRAM soft key
The control displays the selected NC program on
the screen.
Scroll through the NC program with the arrow
keys
Press the END PGM PAL soft key
The control returns to the pallet table.
A machine parameter defines how the control is to react
after an error.
HEIDENHAIN | TNC 640 | ISO Programming User's Manual | 10/2017