30-18 Firmware and Configuration File Maintenance

Figure 30-18 Menu 24.7.2 As Seen Using the Console Port

Menu 24.7.2 - System Maintenance - Upload System Configuration File
To upload system configuration file:
1. Enter "y" at the prompt below to go into debug mode.
2. Enter "atlc" after "Enter Debug Mode" message.
3. Wait for "Starting XMODEM upload" message before activating
Xmodem upload on your terminal.
4. After successful firmware upload, enter "atgo" to restart the
system.
Warning:
1. Proceeding with the upload will erase the current
configuration file.
2. The system's console port speed (Menu 24.2.2) may change
when it is restarted; please adjust your terminal's speed
accordingly. The password may change (menu 23), also.
3. When uploading the DEFAULT configuration file, the console
port speed will be reset to 9600 bps and the password to
"setup".
Step 2.
After the "Starting Xmodem upload" message appears, activate the Xmodem protocol
on your computer. Follow the procedure as shown previously for the HyperTerminal
program. The procedure for other serial communications programs should be similar.
Step 3.
Enter "atgo" to restart the Contivity 221.
30.2.23
Example Xmodem Configuration Upload Using
HyperTerminal
Click Transfer, then Send File to display the following screen.
317517-A Rev 00
Do You Wish To Proceed:(Y/N)