Siemens SIMATIC S5-100U System Manual page 328

Simatic s5 series cpu 100/102/103
Hide thumbs Also See for SIMATIC S5-100U:
Table of Contents

Advertisement

The Integral Real-Time Clock
FB11 STL
NAME :SET PROMPT TIME
DES
:WDAY
I/Q/D/B/T/C: I
DES
:DATE
I/Q/D/B/T/C: I
DES
:MON
I/Q/D/B/T/C: I
DES
:HOUR
I/Q/D/B/T/C: I
DES
:AMPM
I/Q/D/B/T/C: I
DES
:MIN
I/Q/D/B/T/C: I
DES
:SEC
I/Q/D/B/T/C: I
DES
:ERR
I/Q/D/B/T/C: Q
DES
:ALRM
I/Q/D/B/T/C: Q
DES
:MODE
I/Q/D/B/T/C: I
:A
=MODE
:=
F
11.1
:A
F
10.5
:S
=ALRM
:R
F
10.5
:
:AN
F
20.1
:JC
=M001
:R
F
20.1
:
:C
DB
2
:L
=WDAY
:T
DR
8
:L
=DAY
:T
DL
9
:L
=MON
:T
DR
9
12-28
SETTING THE PROMPT TIME
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BI
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BI
BI/BY/W/D: BI
BI/BY/W/D: BI
24 HOUR MODE = 0, 12 HOUR = 1
(SET CLOCK MODE)
DISPLAY PROMPT TIME REACHED
(BIT 13 IN STATUS WORD)
RESET BIT AFTER EVALUATION
FLAG IS RESET IF SETTINGS HAVE ALREADY
BEEN READ INTO THE CLOCK DATA AREA
CLOCK DATA AREA
STORE VALUE FOR WEEKDAY
STORE VALUE FOR DATE
STORE VALUE FOR MONTH
Explanation
EWA 4NEB 812 6120-02b