Number Representation - Siemens SIMATIC S5-100U System Manual

Simatic s5 series cpu 100/102/103
Hide thumbs Also See for SIMATIC S5-100U:
Table of Contents

Advertisement

S5-100U
You can use the COMPRESS programmer function to clean up internal program memory.
If there is a power failure during the compress operation when a block is being shifted and block
shifting can not be completed, the CPU remains in the STOP mode. The "NINEU" error message
appears. Both the"BSTSCH" and the "SCHTAE" bits are set in the ISTACK.
Remedy: Overall reset.
7.6

Number Representation

With STEP 5 you can work with numbers in the following five representations:
Decimal numbers from -32768 to +32767 (KF)
Hexadecimal numbers from 0000 to FFFF (KH)
BCD-coded numbers (4 tetrads) from 0000 to 9999
Bit patterns (KM)
Constant byte (two-byte representation) from 0 to 255 for each byte (KY)
Number Formats
The programmable controller is designed to process binary signal states (only "0" and "1").
Therefore the programmable controller represents all numbers internally as 16-bit binary numbers or
as bit patterns.
Four bits can be combined into a tetrad (BCD) to shorten the binary code representation. The value
of these tetrads can be displayed in hexadecimal representation.
Example:
16-bit binary coded number and shortened hexadecimal representation
Word no.
Byte no.
Bit no.
Binary code representation
Meaning
Hexadecimal representation
Figure 7-16. Bit Assignment of a 16-Bit Fixed-Point Binary Number
EWA 4NEB 812 6120-02b
n
(high byte)
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0
0
0
1
1
1
15
14
13
12
11
10
2
2
2
2
2
2
1
Introduction to STEP 5
n
n+ 1 (low byte)
1
1
0
1
1
0
9
8
7
6
5
2
2
2
2
2
2
F
6
0
0
1
1
4
3
2
1
0
2
2
2
2
3
7-31