Characteristics and Specifications
Trigger system (continued)
Selections
Edge
Pattern
Pulse width
TV
Sequence
CAN
LIN
USB
2
I
C
SPI
350
Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I
burst.
Trigger on a rising, falling, alternating or either edge of any source
Trigger at the beginning of a pattern of high, low, and don't care levels and/or a rising or
falling edge established across any of the analog and digital channels, but only after a
pattern has been established for a minimum of 2 nsec.
The oscilloscope channel's high or low level is defined by that channel's trigger level.
The logic channel's trigger level is defined by the threshold for the pod, 0 - 7 or 8 - 15.
Trigger when a positive- or negative-going pulse is less than, greater than, or within a
specified range on any of the source channels.
Minimum pulse width setting:
5 ns (MSO/DSO601xA/603xA oscilloscope channels)
2 ns (MSO/DSO605xA/610xA oscilloscope channels)
2 ns (logic channels on MSO6000A or
MSO-upgraded DSO6000A)
Maximum pulse width setting: 10 s
Trigger using any oscilloscope channel on most analog progressive and interlaced video
standards including HDTV/EDTV, NTSC, PAL, PAL-M or SECAM broadcast standards.
Select either positive or negative sync pulse polarity. Modes supported include Field 1,
Field 2, all fields, all lines, or any line within a field. TV trigger sensitivity: 0.5 division of
sync signal. Trigger holdoff time can be adjusted in half field increments.
Arm on event A, trigger on event B, with option to reset on event C or time delay.
Trigger on CAN (Controller Area Network) version 2.0A and 2.0B signals. Trigger on the
start of frame (SOF) bit (standard). N5424A option supports triggering on remote frame
ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame ID and data, error
frame, all errors, acknowledge error and overload frame.
Trigger on LIN (Local Interconnect Network) sync break at beginning of message frame
(standard). N5424A option supports triggering on frame ID.
Trigger on USB (Universal Serial Bus) start of packet, end of packet, reset complete,
enter suspend, or exit suspend on the differential USB data lines. USB low speed and full
speed are supported.
2
Trigger on I
C (Inter-IC bus) serial protocol at a start/stop condition or user defined
frame with address and/or data values. Also trigger on missing acknowledge, restart,
EEPROM read, and 10-bit write.
Trigger on SPI (Serial Protocol Interface) data pattern during a specific framing period.
Supports positive and negative Chip Select framing as well as clock Idle framing and
user-specified number of bits per frame.
2
C, SPI, Nth edge