Reference
8
File Size
A 32-bit integer that is the number of bytes that are in
the file.
Number of Waveforms
A 32-bit integer that is the number of
waveforms that are stored in the file.
Waveform Header
It is possible to store more than one waveform in the file, and
each waveform stored will have a waveform header. The
waveform header contains information about the type of
waveform data that is stored following the waveform data
header.
Header Size
A 32-bit integer that is the number of bytes in the
header.
Waveform Type
A 32-bit integer that is the type of waveform
stored in the file:
• 0 = Unknown.
• 1 = Normal.
• 2 = Peak Detect.
• 3 = Average.
• 4 = Not used in 6000 Series oscilloscopes.
• 5 = Not used in 6000 Series oscilloscopes.
• 6 = Logic.
Number of Waveform Buffers
A 32-bit integer that is the number
of waveform buffers required to read the data.
Points
A 32-bit integer that is the number of waveform points
in the data.
Count
A 32-bit integer that is the number of hits at each time
bucket in the waveform record when the waveform was created
using an acquisition mode like averaging. For example, when
averaging, a count of four would mean every waveform data
point in the waveform record has been averaged at least four
times. The default value is 0.
6000 Series Oscilloscope User's Guide