Cycle Parameters; Logging Function - HEIDENHAIN TNC 620 User Manual

Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

17
Touch Probe Cycles: Automatic Kinematics Measurement | SAVE KINEMATICS (Cycle 450, DIN/ISO: G450,

Cycle parameters

Q410 Mode (0/1/2/3)?: Define if you wish to
backup or restore the kinematics:
0: Backup active kinematics
1: Restore saved kinematics
2: Display current memory status
3: Delete a data record
Q409/QS409 Name of data record?: Number or
name of the data block designator. For numbers
you can enter values from 0 to 99999, and when
entering letters the string length may be no longer
than 16 characters 16 memory spaces in total
are available. Q409 has no function if Mode 2
has been selected. Wildcards can be used for
searches in Modes 1 and 3 (Restore and Delete).
If the TNC finds several possible data records
because of the wildcards, the TNC restores the
mean values of the data (Mode 1) or deletes all
data blocks after confirmation (Mode 3). You can
use the following wildcards for searching:
?: A single indefinite character
$: A single alphabetic character (letter)
#: A single indefinite number
*: An indefinite character string of any length

Logging function

After running Cycle 450, the TNC will create a measuring log
(tchprAUTO.html) containing the following information:
Creation date and time of the log
Name of the NC program from which the cycle was run
Designator of the current kinematics
Active tool
The other data in the log vary depending on the selected mode:
Mode 0: Logging of all axis entries and transformation entries of
the kinematics chain that the TNC has saved.
Mode 1: Logging of all transformation entries before and after
restoring the kinematics configuration.
Mode 2: List of the saved data records.
Mode 3: List of the deleted data records.
494
Saving the current kinematics
5 TCH PROBE 450 SAVE KINEMATICS
Q410=0
Q409=947
Restoring data blocks
5 TCH PROBE 450 SAVE KINEMATICS
Q410=1
Q409=948
Displaying all saved data blocks
5 TCH PROBE 450 SAVE KINEMATICS
Q410=2
Q409=949
Deleting data blocks
5 TCH PROBE 450 SAVE KINEMATICS
Q410=3
Q409=950
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 10/2017
option)
;MODE
;MEMORY DESIGNATION
;MODE
;MEMORY DESIGNATION
;MODE
;MEMORY DESIGNATION
;MODE
;MEMORY DESIGNATION