Cycle Parameters - HEIDENHAIN TNC 620 User Manual

Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

15
Touch Probe Cycles: Automatic Workpiece Inspection | MEASURE COORDINATE (Cycle 427, DIN/ISO: G427,

Cycle parameters

Q263 1st measuring point in 1st axis? (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
Q264 1st measuring point in 2nd axis?
(absolute): Coordinate of the first touch point in
the minor axis of the working plane. Input range
-99999.9999 to 99999.9999
Q261 Measuring height in probe axis? (absolute):
Coordinate of the ball tip center (= touch point) in
the touch probe axis in which the measurement
is to be made. Input range -99999.9999 to
99999.9999
Q320 Set-up clearance? (incremental): Define
an additional distance between measuring point
and ball tip. Q320 is added to SET_UP in the touch
probe table. Input range 0 to 99999.9999
Q272 Meas. axis (1/2/3, 1=ref. axis)?: Axis in
which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis
3: Touch probe axis = measuring axis
Q267 Trav. direction 1 (+1=+ / -1=-)?: Direction
in which the probe is to approach the workpiece:
-1: Negative traverse direction
+1: Positive traverse direction
Q260 Clearance height? (absolute): coordinate in
the touch probe axis at which no collision between
tool and workpiece (fixtures) can occur. Input
range -99999.9999 to 99999.9999
Q281Measuring log (0/1/2)?: Definition of
whether TNC should create a measuring log:
0: Create no measuring log
1: Create measuring log: The TNC will save the
log file TCHPR427.TXT
TNC:\.
2: Interrupt the program run and display the
measuring log on the TNC screen. Resume
program run with NC Start.
458
by default in the directory
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 10/2017
software option 17)
NC blocks
5 TCH PROBE 427 MEASURE
COORDINATE
Q263=+35
;1ST POINT 1ST AXIS
Q264=+45
;1ST POINT 2ND AXIS
Q261=+5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q272=3
;MEASURING AXIS
Q267=-1
;TRAVERSE DIRECTION
Q260=+20
;CLEARANCE HEIGHT
Q281=1
;MEASURING LOG
Q288=5.1
;MAXIMUM LIMIT
Q289=4.95
;MINIMUM LIMIT