Touch Probe Cycles: Automatic Kinematics Measurement | PRESET COMPENSATION (Cycle 452, DIN/
ISO: G452, option)
Parameter
Meaning
number
Q141
Standard deviation measured in the A axis
(–1 if axis was not measured)
Q142
Standard deviation measured in the B axis
(–1 if axis was not measured)
Q143
Standard deviation measured in the C axis
(–1 if axis was not measured)
Q144
Optimized standard deviation in the A axis
(–1 if axis was not measured)
Q145
Optimized standard deviation in the B axis
(–1 if axis was not measured)
Q146
Optimized standard deviation in the C axis
(–1 if axis was not measured)
Q147
Offset error in X direction, for manual trans-
fer to the corresponding machine parameter
Q148
Offset error in Y direction, for manual trans-
fer to the corresponding machine parameter
Q149
Offset error in Z direction, for manual trans-
fer to the corresponding machine parameter