Advertisement

Touch Probe Cycles: Automatic Kinematics Measurement | MEASURE KINEMATICS (Cycle 451, DIN/ISO:
G451, option)

Logging function

After running Cycle 451, the TNC creates a measuring log
containing the following information:
(TCHPR451.TXT)
Creation date and time of the log
Path of the NC program from which the cycle was run
Mode used (0=Check/1=Optimize position/2=Optimize pose)
Active kinematic number
Entered calibration sphere radius
For each measured rotary axis:
Starting angle
End angle
Angle of incidence
Number of measuring points
Dispersion (standard deviation)
Maximum error
Angular error
Averaged backlash
Averaged positioning error
Measuring circle radius
Compensation values in all axes (preset shift)
Position before optimization of the rotary axes checked
(relative to the beginning of the kinematic transformation
chain, usually the spindle nose)
Position after optimization of the rotary axes checked
(relative to the beginning of the kinematic transformation
chain, usually the spindle nose)