Touch Probe Cycles: Automatic Workpiece Inspection | MEASURE COORDINATE (Cycle 427, DIN/ISO: G427,
software option 17)
Q288 Maximum limit of size?: Maximum
permissible measured value. Input range
-99999.9999 to 99999.9999
Q289 Minimum limit of size?: Minimum
permissible measured value. Input range
-99999.9999 to 99999.9999
Q309 PGM stop if tolerance exceeded?:
Definition of whether in the event of a violation of
tolerance limits the TNC is to interrupt program
run and output an error message:
0: Do not interrupt program run, do not output an
error message
1: Interrupt program run and output an error
message
Q330 Tool for monitoring?: Definition of
whether the TNC is to monitor the tool (see "Tool
monitoring", Page 430). Input range 0 to 32767 .9,
alternatively tool name with maximum of 16
characters
0: Monitoring inactive
>0: Number or name of the tool that the TNC used
for machining. You are able to apply a tool via soft
key directly from the tool table.
Parameters
cycle. You do not need to make any entries. These
parameters have only been integrated for reasons
of compatibility. If, for example, you import a
program of the contouring control for turning and
milling, TNC 640, you will not receive an error
message.
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 10/2017
and
have no effect in this
Q498
Q531
Q309=0
;PGM STOP TOLERANCE
Q330=0
;TOOL
Q498=0
;REVERSE TOOL
Q531=0
;ANGLE OF INCIDENCE