Touch Probe Cycles: Automatic Workpiece Inspection | MEASURE RECTANGLE OUTSIDE (Cycle 424, DIN/
Q286 Max. size limit 2nd side length?: Maximum
permissible width of the stud. Input range 0 to
99999.9999
Q287 Min. size limit 2nd side length?: Minimum
permissible width of the stud. Input range 0 to
99999.9999
Q279 Tolerance for center 1st axis?: Permissible
position deviation in the reference axis of the
working plane. Input range 0 to 99999.9999
Q280 Tolerance for center 2nd axis?: Permissible
position deviation in the minor axis of the working
plane. Input range 0 to 99999.9999
Q281 Measuring log (0/1/2)?: Definition of
whether TNC should create a measuring log:
0: Create no measuring log
1: Create measuring log: The TNC will save the
log file TCHPR424.TXT
TNC:\.
2: Interrupt the program run and display the
measuring log on the TNC screen. Resume
program run with NC Start.
Q309 PGM stop if tolerance exceeded?:
Definition of whether in the event of a violation of
tolerance limits the TNC is to interrupt program
run and output an error message:
0: Do not interrupt program run, do not output an
error message
1: Interrupt program run and output an error
message
Q330 Tool for monitoring?: Definition of
whether the TNC is to monitor the tool (see "Tool
monitoring", Page 430). Input range 0 to 32767 .9,
alternatively tool name with maximum of 16
characters
0: Monitoring inactive
>0: Number or name of the tool that the TNC used
for machining. You are able to apply a tool via soft
key directly from the tool table.
450
by default in the directory
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 10/2017
ISO: G424, software option 17)
Q286=35
;MAX. LIMIT 2ND SIDE
Q287=34.95;MIN. LIMIT 2ND SIDE
Q279=0.1
;TOLERANCE 1ST CENTER
Q280=0.1
;TOLERANCE 2ND CENTER
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP TOLERANCE
Q330=0
;TOOL