AS-Interface Protocol Implementation Conformance
Statements
A.1
AS-Interface Protocol Implementation Conformance Statement
(PICS)
PICS for the CM AS-i Master ST
Vendor
Product name
Article number
Firmware version
Master profile
Date
List of available master functions
Character
X
No.
Function or command to the host interface (symbolic
representation)
1
Image, Status = Read_IDI()
2
Status = Write_ODI(Image)
3
Status = Set_Permanent_Parameter (Addr, Param)
4
Param, Status = Get_Permanent_Parameter (Addr)
5
Status, Param = Write_Parameter (Addr, Param)
6
Status, Param = Read_Parameter(Addr)
7
Status = Store_Actual_Parameters()
8
Status = Set_Permanent_Configuration (Addr, Config)
9
Status, Config = Get_Permanent_Configuration (Addr)
10
Status = Store_Actual_Configuration()
AS-Interface master CM AS-i Master ST (3RK7137-6SA00-0BC1)
Manual, 07/2017, A5E02655262020A/RS-AD/004
SIEMENS AG
CM AS-i Master ST
3RK137-6SA00-0BC1
V1.0, V1.1
M4
Meaning
Function available
Function not available
M4
Remark / implementation of the function with
X
Through automation system access to the I/O
data of the AS-i master
X
Through automation system access to the I/O
data of the AS-i master
X
See Section "Description of the AS-i commands
(Page 103)"
X
X
X
X
X
X
STEP 7
X
In
, in the control panel, by pressing the
"ACTUAL → CONFIGURED" button.
A