OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
9.3.4

OPC UA server instructions for the implementation of methods

9.3.4.1

OPC_UA_ServerMethodPre

Introduction
This section describes the instruction "OPC_UA_ServerMethodPre".
Because the instructions "OPC_UA_ServerMethodPre" and "OPC_UA_ServerMethodPost"
always have to be called up in pairs in the user program, please also take into account the
section on the instruction "OPC_UA_ServerMethodPost".
Function of the instruction
The instruction "OPC_UA_ServerMethodPre" queries the operating system to determine
whether or not the server method was called.
If the server method was called by the client, the instruction "OPC_UA_ServerMethodPre"
provides the input parameters for the server method.
Declaration of tags
Declare an instance of the instruction "OPC_UA_ServerMethodPre" and the tags with which
you supply the instruction parameters, see also Example program for providing a method for
OPC UA clients (Page 190).