6.14 Jog run mode

f260 : Jog run frequency
f261 : Jog run stopping pattern
f262 : Panel jog run mode
 Function
Use the jog run parameters to operate the motor in jog mode. Input of a jog run signal immediately
generates a jog run frequency output irrespective of the designated acceleration time.
Also, you can choose the jog run start/stop mode from the panel.
Assign 18: jog run mode to an input terminal.
Ex) When assigning it to the RES terminal: f113 to 18.
The motor can be operated in jog mode while the assigned input terminals are connected (RES-CC ON).
[Parameter setting]
Title
Jog run frequency
f260
Jog run stopping
f261
pattern
Panel jug run mode
f262
[Setting of jog run mode (RES-CC)]
Ex) Assign jog run mode to control terminal RES.
Title
f113
Input terminal selection (RES)
Note 1: During the jog run mode, low speed detection signal (LOW) is output but designated frequency reach
signal (RCH) is not output, and PID control does not work.
Note 2: When only the operation panel is used for operation in jog run mode, the jog run function does not need to
be assigned to any input terminal.
<Examples of jog run>
RES (JOG): ON + F:ON: Forward jog run
RES(JOG): ON + R: ON: Reverse jog run
( Frequency command + F: ON: Forward run, Frequency command + R: ON: Reverse run )
Function
f240-20.0 (Hz)
0: Deceleration stop
1: Coast stop
2: DC braking
0: Invalid
1: Valid
Function
0-203
F-49
Adjustment range
Default setting
Adjustment range
(Jog run mode)
E6581926
6
5.0
0
0
Setting