Panel emergency stop operation
f734 
prohibition
f735  Panel reset operation prohibition
cmod / fmod change prohibition
f736 
during operation
All key operation prohibition

f738  Password setting ( f700 )
f739  Password verification
 Parameters can be edited regardless of the setting of f700 by assigning the parameter editing
permission (function number 110, 111) to an input terminal.
Note1: f700 = 2 and 4 will be available after reset operation.
Note 2: Turn off and turn on again after the f737 setting to take effect the setting.
Note 3: The frequency setting( fc , fpid , Preset-speed frequency) by the setting dial in the standard
monitor mode cannot be prohibited by f700 .
Set 1 f731 = 1 to prohibit the frequency setting.
1) Setup and resetting method when protection using a password is necessary
■ Password setup method
Preparation: Parameters other than f700 , f738 , and f739 cannot be changed when f700 is set
to 1 to 4 .
(1)
When f738 or f739 is read out and the value is 0 , a password hasn't been set.
You can set a password.
(2)
When f738 or f739 is read out and the value is 9999 , a password has already been set.
(3)
You can set a password If it hasn't been set. Select and register a number from 1 to 9998 for f738 .
The number is the password. Do not forget your password as it is required to release the lock.
(4)
The settings for parameter f700 cannot be changed.
Note4: The lock cannot be released If you forget the password. Do not forget this password as we cannot
retrieve it.
Note5: Password cannot be set when parameter f700 = 0 .
Set the password after parameter f700 = 1 to 4 .
Note6: Password can be read out to parameter writer (optional device) only for 5 minutes after setting
. Please note that password will not be able to read out due to password protection after 5
minutes have elapsed or when the power is off.
■ Password examination method
(1)
When f738 or f739 are read out and the value is 9999 , a password has already been set.
Password has to be removed in order to change parameters.
(2)
Enter a the number ( 1 to 9998 ) registered to f739 when the password was set for f738 .
(3)
If the password matches, pass blinks on the display and the password is removed.
(4)
If the password is incorrect, fail blinks on the display and f739 is displayed again.
Function
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Password unset
1-9998
9999: Password set
0: Password unset
1-9998
9999: Password set
F-123
Adjustment range
Default setting
E6581926
0
0
1
0
0
0
6