Jog Run Mode - Toshiba VF-PS1 Instruction Manual

Variable torque inverter
Hide thumbs Also See for VF-PS1:
Table of Contents

Advertisement

6.10

Jog run mode

 : Jog run frequency
 : Jog run stop pattern
 : Operation panel jog run mode
• Function
Use the jog run parameters to operate the motor in jog mode. Input of a jog run signal generates a jog run
frequency output at once, irrespective of the designated acceleration time.
Also, you can choose an operation panel start/stop mode between the ordinary start/stop mode and the jog
run start/stop mode.
The jog run function needs to be assigned to an input terminal.
When assigning it to the S3 terminal, set  to .
The motor can be operated in jog run mode while the jog run setting terminals are connected (S3-CC: ON).
[Parameter setting]
Title



<Examples of jog run>
6
S3-CC (JOG) ON + F-CC ON: Forward jog run
S3-CC (JOG) ON + R-CC ON: Reverse jog run
( Normal operation frequency signal input + F-CC ON: Forward run, Normal operation frequency signal input + R-CC ON: Reverse run )
Output frequency [Hz]
Set frequency
Input of operation
frequency setting signal
• The jog run setting terminal (S3-CC) is enabled when the operation frequency is below the jog run frequency.
This connection does not function at an operation frequency exceeding the jog run frequency.
• The motor can be operated in jog mode while the jog run setting terminals are connected (S3-CC: ON).
• Jog run has priority, even when a new operation command is given during operation.
• Even during panel operation ( =), the inverter can be switched forcibly to jog run mode by turning on or
off the input terminal if parameter  (input terminal priority selection) is set to  and the jog run setting
function (, ) is assigned to the input terminal.
• Even for = or , an emergency DC braking becomes enabled when setting =.
• If a forward run command and a reverse run command are entered simultaneously while  (priority selection
(both F-CC and R-CC are ON)) is set to  (reverse run), operation modes are switched as follows: forward jog run
→ deceleration stop (jog frequency → 0Hz) → reverse jog run. Keep this in mind.
• The jog frequency is not restricted by the upper limit frequency ().
Function
Jog run frequency
Jog run stop pattern
Operation panel jog run mode
Forward
Forward
run
run
0
F-CC
R-CC
S3-CC
Adjustment range
~ Hz
:Deceleration stop, : Coast stop,
:DC braking stop
:Disabled,
:Operation panel jog run mode enabled
Forward run
Reverse
run
F-18
E6581386
Default setting

Time [s]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents