(3) Coast stop
Assign parameters as described below in case of
Coast stop. Inverter will display off at Coast stop.
1) Assign "6 (ST)" to an input terminal. Set parameter
=. Open the ST-CC for coast stop(see the
status described on the right).
2) Assign "96 (FRR)" to an input terminal.
Coast stop is done by shorting FRR and CC.
3.1.2
3
[Example of fmod setting procedure] fmod=1: Setting the frequency by the terminal VIA
Panel operation
MODE
*Pressing the MODE key twice returns the display to standard monitor mode (displaying output frequency).
(1) Setting using the keypad or extension panel option (fmod=0 or 3)
For an extension panel option,
Example of operating from the panel (=: press in center to save)
Panel operation
How to set the frequency
LED display
Displays the output frequency (operation stopped).
00
(When standard monitor display selection f710=0 [output frequency])
Displays the first basic parameter [History (auh)].
auh
Turn the setting dial, and select "fmod".
fmod
Press the center of the setting dial to read the parameter value.
0
(Standard default: 0).
Turn the setting dial to change the parameter value to (terminal VIA).
1
The parameter value is written. fmod and the parameter value are
1fmod
displayed alternately several times.
: Moves the frequency up
key moves the frequency up,
LED display
Motor
speed
F-CC
ST-CC
Operation
: Moves the frequency down
Operation
Displays the output frequency.
(When standard monitor display selection = [output frequency])
Set the output frequency. (The frequency will not be saved if the
power is turned off in this state.)
Save the output frequency. and the frequency are displayed
alternately.
C-4
E6581926
Coast stop
key moves the frequency down.
ON
OFF
ON
OFF