1
4:
● The control input terminal in which the following functions are set is always valid regardless of the setting of
and .
Reset (valid only for tripping)
Standby
6
External input tripping stop command
Coast stop command terminal
● To make changes in the command mode selection and the frequency setting mode selection 1
, first stop the inverter temporarily.
(Can be changed while in operation when is set to .)
● Priority commands from communications or terminal blocks are given priority over .
Preset-speed operation
: Set to (Terminal block operation)
: Valid in all setting values.
Input terminal settings
Assign the following functions to the input terminal to allow switching of the frequency command by turning
the terminal ON/OFF.
48
106
Each of the following numbers (49, 107) are reverse signals.
Communication
Frequencies are set by commands from a communication option.
option
Refer to each Instruction Manual of option.
A frequency command is set by means of external analog signals.
Terminal VIC
(VIC terminal: 0 (4) - 20mAdc)
Refer to section 3.1.2 and 7.3
A frequency command is set by means of external pulse train signals.
Pulse train input
(S2 terminal: 10pps - 2kpps)
Refer to section 6.10.5
Frequencies are set by sro parameter.
sro
Refer to section 5.7
Input terminal function
Forced local from communication
Frequency setting mode terminal
block
ON
Enabled during communication
Local (Setting of , )
Terminal block (VIA) enabled
F-14
E6581926
OFF
Communication
setting of