Toshiba Tosvert VF-S15 Instruction Manual page 312

Industrial inverter (for 3-phase induction motors)
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

Communication
Title
No.
0627

0629

0631

0632

0633

0634

0643

0644

0645

0646

0648

0649

0650

0656

0657

0660

11
0661

0663

*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Undervoltage
-
trip/alarm
selection
Factory specific
-
coefficient 6B
Inverter overload
-
detection method
Electronic-thermal
-
memory
Analog input break
%
1/1
detection level (VIC)
Annual average
-
ambient
temperature (parts
replacement
alarms)
Factory specific
-
coefficient 6C
Operation
-
selection of
analog input break
detection (VIC)
PTC thermal
-
selection
PTC detection
1/1
resistor value
Number of starting
10000
0.1/0.1
alarm
times
Fallback frequency
Hz
0.1/0.01
Forced fire-speed
-
control selection
Factory specific
-
coefficient 6D
Overload alarm level
%
1/1
Override addition
-
input selection
Override
-
multiplication input
selection
Analog input
-
terminal function
selection (VIB)
Adjustment range
-
0: Alarm only(detection level 60% or less)
1: Tripping (detection level 60% or less)
2: Alarm only(detection level 50% or
less, input AC or DC reactor required)
3: -
-
-
-
0: 150%-60s (120%-60s)
1: Temperature estimation
-
0: Disabled (thr, f173)
1: Enabled (thr, f173)
2: Disabled (thr)
3: Enabled (thr)
0: Disabled,
1-100
-
1: -10 to +10C
2: 11-20C
3: 21-30C
4: 31-40C
5: 41-50C
6: 51-60C
-
-
-
0: Tripping
1: Alarm only (Coast stop)
2: Alarm only (f649 frequency)
3: Alarm only (Maintain running)
4: Alarm only (Deceleration stop)
-
1: Tripping
2: Alarm only
100-9999
0.0-999.0
ll-
-
0: Disabled
1: Enabled
-
-
10-100
-
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: fc
-
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4: f729
-
0: Frequency command
1: Acceleration/deceleration time
2: Upper limit frequency
3, 4: -
5: Torque boost value
6: Stall prevention level
7: Motor electronic-thermal protection
level
8 to 10: -
11: Base frequency voltage
12 to 23: -
K-18
E6581926
Default
User
Reference
setting
setting
0
6.29.13
-
* 3
0
5.6
0
5.6
6.29.1
0
6.29.14
3
6.29.15
-
* 3
0
6.29.14
1
6.29.16
3000
999.0
6.29.17
0.0
6.29.14
0
6.30
-
* 3
50
5.6
0
6.31
0
0
6.32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents