17 IR Remote Controller (REMC3)

17.1 Overview

The REMC3 circuit generates infrared remote control output signals. This circuit can also be applicable to an EL
lamp drive circuit by adding a simple external circuit.
The features of the REMC3 are listed below.
• Outputs an infrared remote control signal.
• Includes a carrier generator.
• Flexible carrier signal generation and data pulse width modulation.
• Automatic data setting function for continuous data transmission.
• Output signal inverting function supporting various formats.
• EL lamp drive waveform can be generated for an application example.
Figure 17.1.1 shows the REMC3 configuration.
Table 17.1.1 REMC3 Channel Configuration of S1C17M20/M21/M22/M23/M24/M25
Item
Number of channels
Clock
generator
Interrupt
controller

17.2 Input/Output Pins and External Connections

17.2.1 Output Pin

Table 17.2.1.1 shows the REMC3 pin.
Pin name
I/O*
REMO
O
CLPLS
O
S1C17M20/M21/M22/M23/M24/M25
TECHNICAL MANUAL (Rev. 1.0)
S1C17M20/M23
24-pin package
32-pin package
REMC3
CLK_REMC3
CLKSRC[1:0]
Carrier signal
CLKDIV[3:0]
DBRUN
MODEN
DBLENBSY
APLENBSY
REMCRST
DBCNT[15:0]
DBCNTRUN
DBIE
control circuit
APIE
Figure 17.1.1 REMC3 Configuration
Table 17.2.1.1 REMC3 Pin
Initial status*
O (L)
IR remote controller transmit data output
O (L)
IR remote controller clear pulse output
* Indicates the status when the pin is configured for the REMC3.
Seiko Epson Corporation
17 IR REMOTE CONTROLLER (REMC3)
S1C17M21/M24
1 transmitter channel
CRPER[7:0]
CRDTY[7:0]
generator
DBLEN[15:0]
APLEN[15:0]
Data signal
REMOINV
generator
OUTINVEN
Interrupt
Function
S1C17M22/M25
CARREN
PRESET
PRUN
BUFEN
REMO
CLPLS
TRMD
DBIF
APIF
17-1